GST Pyro Specification(S/N : 1C853S0161) | ||
No. | Discription | 1 |
1. | Manufacturer | KE |
2. | Model | DD-853V / J2 |
3. | Serial No. | 1C853S0161 |
4. | Vintage | 99.10 |
5. | Process Name / EQP No. | PYRO |
6. | Equipment Status | CND WAREHOUSE |
7. | System Controller | |
1 | Main Controller | CX-3002B |
2 | Mecha Controller | CX-1223 |
3 | Temp Controller | CQ-1600 |
4 | Over Temp Protect | DN-150A |
5 | MFC / APC Controller | CX-3202 |
6 | Sequence Controller | CX-1314(OMRON) |
7 | Burning Controller | CX-1317 |
8. | General Configuration | |
1 | Heater Type(Model) | D4EX03513 |
2 | Heating Zone | 4 ZONE |
3 | Signal Tower | 3COLOR(R,G,Y) |
4 | Heater Status | EXIST |
5 | WTR Fork. | 1+4 |
6 | Fork Variable Pitch | EXIST |
7 | Fork Wafer Sensor | EXIST |
8 | Cassette Slot Qt'y | 26Pc |
9 | Stage Qt'y | 23 |
10 | Load Type (SMIF / I/O) | I/O |
11 | Aligner | Flatzone / 26Pc |
12 | Gas Detector | H2(1ea) / HCL(1ea) |
13 | Hard Gas Pattern | (Front, Rear) |
14 | CX-3002P (Monitor) | Rear |
15 | Pump Unit | NONE |
16 | Torch Unit | EXIST (LAMP TYPE) |
17 | Heating Jacket(Tape Heater) | NONE |
18 | Gas Tubing | IGS (Fujikin) |
9. | Process Gasses | |
1 | Process Gas 1 | N2 |
2 | Process Gas 2 | O2 |
3 | Process Gas 3 | H2 |
4 | Process Gas 4 | HCL |
5 | Process Gas 5 | |
10. | MFC | |
1 | MFC 1 | Aera N2 30SLM |
2 | MFC 2 | Aera O2 20SLM |
3 | MFC 3 | Aera O2 2SLM |
4 | MFC 4 | Aera H2 20SLM |
5 | MFC 5 | Aera HCL 0.5SLM |
6 | MFC 6 | |
11. | Boat / Pedestal | |
1 | Boat Slot | 172 |
2 | Qty of Production Wafers | 150 |
3 | Boat rotation | NONE |
12. | Temp Control | |
1 | T/C(Spike, Over temp) | O.K |
2 | Flange Temp Controller | EXIST |
13. | Exhaust Parts | |
1 | Gas Cooler | EXIST |
2 | Exhaust Line | 1" Teflon |
3 | APC Valve | Stec (PCU-3000 / EC-5202), (50mmH2O) |
14. | Power | |
1 | Voltage (Heater) | 1Φ208V (50KVA) |
2 | Voltage (Controller Main) | 1Φ208V (3KVA) |
3 | Voltage (Clean Unit) | 1Φ208V (6KVA) |
15. | Missing / Fail Parts | |
1 | ||
2 | ||
3 | ||
4 | ||
16. | ETC | |
1 | ||
2 |
GST Pyro Specification(T2DC3-11445-3) | ||
No. | Discription | 1 |
1. | Manufacturer | KE |
2. | Model | DD-853V / J2 |
3. | Serial No. | T2DC3-11445-3 |
4. | Vintage | 2000.10 |
5. | Process Name / EQP No. | PYRO |
6. | Equipment Status | CND WAREHOUSE |
7. | System Controller | |
1 | Main Controller | CX-3002B |
2 | Mecha Controller | CX-1223 |
3 | Temp Controller | CQ-1600 |
4 | Over Temp Protect | DN-150A |
5 | MFC / APC Controller | CX-3202 |
6 | Sequence Controller | CX-1314(OMRON) |
7 | Burning Controller | CX-1317 |
8. | General Configuration | |
1 | Heater Type(Model) | |
2 | Heating Zone | 4 ZONE |
3 | Signal Tower | 3COLOR(R,G,Y) |
4 | Heater Status | EXIST |
5 | WTR Fork. | 1+4 |
6 | Fork Variable Pitch | EXIST |
7 | Fork Wafer Sensor | EXIST |
8 | Cassette Slot Qt'y | 26Pc |
9 | Stage Qt'y | 23 |
10 | Load Type (SMIF / I/O) | I/O |
11 | Aligner | Flatzone / 26Pc |
12 | Gas Detector | H2(1ea) / HCL(1ea) |
13 | Hard Gas Pattern | (Front, Rear) |
14 | CX-3002P (Monitor) | Rear |
15 | Pump Unit | NONE |
16 | Torch Unit | EXIST (LAMP TYPE) |
17 | Heating Jacket(Tape Heater) | NONE |
18 | Gas Tubing | Conventional |
9. | Process Gasses | |
1 | Process Gas 1 | N2 |
2 | Process Gas 2 | O2 |
3 | Process Gas 3 | H2 |
4 | Process Gas 4 | HCL |
5 | Process Gas 5 | |
10. | MFC | |
1 | MFC 1 | N2 30SLM |
2 | MFC 2 | O2 20SLM |
3 | MFC 3 | O2 2SLM |
4 | MFC 4 | H2 20SLM |
5 | MFC 5 | HCL 0.5SLM |
6 | MFC 6 | |
11. | Boat / Pedestal | |
1 | Boat Slot | 172 |
2 | Qty of Production Wafers | 150 |
3 | Boat rotation | NONE |
12. | Temp Control | |
1 | T/C(Spike, Over temp) | O.K |
2 | Flange Temp Controller | EXIST |
13. | Exhaust Parts | |
1 | Gas Cooler | EXIST |
2 | Exhaust Line | 1" Teflon |
3 | APC Valve | Sentry1510, Vertical (50mmH2O) |
14. | Power | |
1 | Voltage (Heater) | 1Φ208V (50KVA) |
2 | Voltage (Controller Main) | 1Φ208V (3KVA) |
3 | Voltage (Clean Unit) | 1Φ208V (6KVA) |
15. | Missing / Fail Parts | |
1 | ||
2 | ||
3 | ||
4 | ||
16. | ETC | |
1 | ||
2 |